Monophasic Defibrillator vs. Biphasic Defibrillator

Monophasic Defibrillators get defined as the type of shocks given to a human under heart treatment that includes only one vector and the sine wave pattern. On the other hand, Biphasic Defibrillators get defined as the type of shocks given to a human under heart treatment that includes at least two vectors and the cosine wave pattern.

Comparison Chart

Basis of Distinction Monophasic Defibrillators Biphasic Defibrillators
Definition The type waveform formed during this process where the shock gets delivered to the heart with the help of just one vector and hence gets the name. The type waveform formed during this process where the shock gets delivered to the heart with the aid of two vectors and hence gets the name.
Usage Different life-threatening cardiac dysrhythmias and ventricular fibrillation. Various life-threatening cardiac dysrhythmias and ventricular fibrillation.
Devices Implantable Defibrillators detects the irregular heart rate. External Defibrillators moves the high-level values without any problems
Nature Most common used process. Most common available process.

What is Monophasic Defibrillators?

Monophasic Defibrillators get defined as the type of shocks given to a human under heart treatment that includes only one vector and the sine wave pattern. It exists in most hospitals and becomes the common and conventional procedure. These waves may not be the most useful in working but have a benefit for places that do not have large amounts of money or patients and therefore cannot invest much. The parent process has become used for different life-threatening cardiac dysrhythmias and ventricular fibrillation. The energy passed to the system during this process gets expressed in joules and therefore one ampere of current passing through the machine of one ohm resistance in one second goes the definition. Doctors do not have the facility to adjust the impedance, and therefore a fixed amount of energy of 360 joules occurs every time and has become recommended for adult patients whereas children do not can take these shocks, therefore, another process that requires less energy are used for lower aged people. The maximum current flows because of just one vector. Therefore, the wave formed usually follows the Sine wave angle and the value increases in the beginning and then gradually reaches the original value once it becomes stable. Various devices exist in the system that helps to deliver the current, and some of them include the implantable and external defibrillator. The first one detects the irregular heart rate whereas the latter one moves the high-level values without any problems.

What is Biphasic Defibrillators?

Biphasic Defibrillators get defined as the type of shocks given to a human under heart treatment that includes at least two vectors and the cosine wave pattern. A type waveform formed during this process where the shock gets delivered to the heart with the help of two vectors and hence gets the name. Initially, they were used in the first devices but now have become common for external defibrillators. The energy passed to the system during this process gets expressed in joules and therefore one ampere of current passing through the machine of one ohm resistance in one second takes the definition. The value of current here keeps changing per the impedance and therefore does not have a fixed value. The waveforms also have two lines that show the same nature but different levels. Both Physio-Control and Philips utilize the biphasic truncated exponential (BTE) waveform initially created for internal defibrillators, however, they use unique vitality settings with the waveform. Physio-Control uses what they term a “high energy” biphasic waveform, which they term ADAPTIV Biphasic. Consider the focus levels on figuring out how to apply the biphasic waveform in an external defibrillator. In 1999 Zoll Medical Inc created an external biphasic defibrillator. To do as such, the waveform was somewhat changed, to a rectilinear biphasic shape – with a specific end goal to diminish the resistance of current through the skin. For instance, for a 200J vitality setting, the ZOLL RBW charges the capacitor to the most extreme voltage paying little heed to patient impedance.

Key Differences between Monophasic Defibrillator and Biphasic Defibrillator

  1. Monophasic Defibrillators get defined as the type of shocks given to a human under heart treatment that includes only one vector and the sine wave pattern. On the other hand, Biphasic Defibrillators get defined as the type of shocks given to a human under heart treatment that includes at least two vectors and the cosine wave pattern.
  2. Monophasic becomes the type waveform formed during this process where the shock gets delivered to the heart with the help of just one vector and hence gets the name.  On the other hand, Biphasic becomes the type waveform formed during this process where the shock gets delivered to the heart with the help of two vectors and hence gets the name.
  3. Both the methods have become used for different life-threatening cardiac dysrhythmias and ventricular fibrillation.
  4. For Monophasic Defibrillators, the wave formed usually follows the SINE angle and the value increases in the beginning and then gradually reaches the original value once it becomes stable. On the other hand, for, Biphasic Defibrillators two distinct waves help with the identification and are not sin waves.
  5. Implantable Defibrillators detects the irregular heart rate for Monophasic Defibrillators. On the other hand, External Defibrillators moves the high-level values without any problems for Biphasic Defibrillators.